IVF Class II Type A2 Biological Safety Cabinets

Main Filter  “HEPA” H-15 & Class -100 with air-borne Particles count 0.3 Micron and with efficiency of  99.99%  with cold DOP and 99.97% with hot DOP Test

Uses Activated Carbon Filter, Helps in the removal of chemical fumes and odors.

Pre Filter fiber cloth 10 micron captures large particles to extend HEPA filter life.

Air  Pressure Analogue Gauge Monitors airflow conditions.

Filter Life Timer with Alarm system to indicate need to change filter

Description

Superior egonomic design & styling

negative pressure double-wall housings for containment

The work table of station made up of stainless steel SS304 grade with Glass heating stage both sides. The thermostat accuracy of +/- 0.30 C.

all stainless steel work zone construction with radiused & crevice-free corners

spacious work zone interior

The workstation constructed with mild Steel coated with rust resistant epoxy powder coated.

The cabinet noise level less than 63 dB(A) for a 4 feet.

Side Flexi Glass:- both side PC glass window.

smooth & effortless sliding tempered glass window, closes completely

THERMOFOIL HEATING SYSTEM for accurate & reliable thermal control of the worktop

2 Nos .Heating Area on work Table: Three side heating arrangement (Both side of stage Heating).

The cabinet automatically reduce fan/blower motor speed to 30% when the front window sash is in a closed position .

ISO Class 5 (Class 100) air cleanliness work zone for absolute product protection

ZERO-LEAK airflow system for enhanced safety

8 Extra Universal sockets

UV light programmable to allow for specific exposure times from 0 to 24 hours. Allows customized sterilization cycles for enhanced biosafety.

UV Germicidal Light integrated to the biosafety cabinet.

The automatic shut off feature on the UV light saves money on replacement of the bulbs.

reliability-proven design & performance

Leveling Pad Workstation antivibration leveling adjustable legs.

The cabinet uses a pressure sensor to detect pressure drop across the supply filter, rather than in just one point across the down flow.

The pressure sensor encased in order to protect the sensor from temperature, humidity and other environmental phenomena that can impact the sensor’s performance.

An automatically adjust the airflow speed without the use of a damper.

The exhaust blower on the cabinet continue operating when the supply blower stops working. Prevents backflow contamination and maintains negative pressure in case of supply blower failure.

The biological safety cabinet capable of achieving current state-of-the-art in energy efficiency.

A biological safety cabinet with lights on and fan at operating speed consume less than 200 watts for a nominal four feet width and have a reduced energy mode for non-operational maintenance on containment in the work area.